Ecobee aux reverse staging. Off Auto Compressor Min On Time.
Ecobee aux reverse staging. *Aux Stage 1 Max Runtime: Sets the maximum time since engaging the first stage of auxiliary heat before engaging the second stage. Aux Stage 1 Max Runtime ‒ Sets the maximum number of minutes running the first stage of auxiliary heat before engaging the second stage. 0 Compressor Reverse Staging - On Compressor Stage 2 Temp Delta - 2. I would be interested to learn about other people's experience. Cool Dissipation Time: Auto Compressor Min On Time: 5min (default) Compressor to Aux Temp Delta: 0F (or as low as you can set it 3F is too high) Compressor to Aux Runtime: Not used (this option is grayed out) Aux Reverse Staging: On Temp Correction: 0F. Then look for Compressor to Aux Delta. I see it as a tradeoff of comfort vs savings. This is my first winter with my Ecobee3 after having my wallet crushed last winter from significant AUX heat run times using an older thermostat. That will reduce aux usage. 0 Exactly. When I get home i have the 2 stage kick in with a 2 degree from set temp my home will get to 73 about 30 minutes to a hour depending on outside temp. Compressor to Aux Temp Delta: 3F Compressor to Aux Runtime: not used (grayed out) Aux Reverse Staging: On Temp Correction: 0F Humidity Correction: 0% Thermal Project: 10F. But honestly, if it's cold enough for your aux to be on, then your normal heat isn't going to help a whole lot and you'll need the aux regardless. 5 degrees above set point it’s only calling stage one. It should only be turning on if absolutely necessary. I live in Richmond, VA I switched my heat on two weeks ago after the temperature outside started dropping below 40 at night and the temperature inside my house started approaching 60. As the stage 1 temperature delta is exceeded, the second stage will engage. 5F. Aux Outdoor Temp Alert (optional): If you have a heat pump with auxiliary heat configuration, you can also program the Smart Si thermostat to generate an alert if the auxiliary heat is called for when the outdoor temperature exceeds this programmed set point. " Apr 8, 2023 В· Setting seem straight forward. Once that I would also add to set the thermostat to enable “reverse staging” in the ecobee advanced menu. You can adjust your Threshold settings in order to make the Aux Heat run less, this Reverse staging. System. The ecobee3 has three different options to achieve this - "Comp to Aux temp delta," "Comp to Aux runtime," and "reverse staging mode. I recently got a new 2 stage heat pump/AC with electric aux heat. It says "With this setting enabled, the ecobee will run auxiliary heating first before staging up to heat pump heating. That allows the the furnace to return to stage 1 DURING the furnace burn once the stage 1 to stage 2 delta is met. The HVAC equipment will start in stage 1. Aux Reverse staging off is good, because otherwise it tells it turns on furnace first until it gets close then tell heat pump to kick in to get it to last bit of set temp. Drop your Min Compressor Temp to 0, Ecobee is locking the compressor out because of your low outdoor temps. So once it’s back down to . Page 17: Advanced Installation and Configuration Instructions A200484 If Manual staging is selected instead of Automatic, then 5 additional staging options for the Auxiliary heat need to be configured. Humidity Correction: 0%. Dec 21, 2015 В· If you’re concerned that your auxiliary heat is running more than it should, you might need to enable the setting that allows the auxiliary heat to run simul engaging the auxiliary heat. Equipment. But reverse staging is actually really good for heat pump systems and maintaining an even temp. Configure Staging - Manually Cool Differential Temp - 1. If you have any heating mode setbacks, you will want to set this to slightly above Auto Aux Reverse Staging When enabled, aux heat will be engaged if the current temperature is greater than the value designated in the Compressor to Aux Temperature Delta setting. It appears to me that ecobee has a bit of work to do here to make the settings more flexible. After that delay, it will energize aux heat but uses reverse staging. When engaging your air-conditioner compressor, the ecobee will energize the Y1 connector, so you'll want to make sure you have the correct wire in the Y1 connector. However, I now understand that the AUX heat will probably never kick in since I never have such a differential. On my system I have the ecobee configured to lock out aux above 5 degrees Fahrenheit, since the heat pump can handle everything above that on it's own. On Temp Correction. I generally set the aux heat lockout to around 20F, then configure reverse staging to allow the heat pump to run while the aux is running because it still provides heat at a cheaper rate until it gets pretty cold outside. " This causes the following events: Temp falls 2. The ecobee will run the second stage of your aux heat if the current temperature is greater than the value designated in the Aux Heat Stage 2 Temperature Delta setting. That is a nice energy saving feature. 0. The furnace would run on the low stage for 5 minutes (IIRC), and if the desired temperature wasn't reached, it would switch to the second stage until the desired temperature was reached. Enable Aux Reverse Staging. (This feature requires an Internet connection to function properly. Reverse staging. Unfortunately I think I may have hit a limitation with ecobee’s thresholds…. Unlike straight cooling projects where Manual Staging is recommended be enabled so Reverse Staging could be utilized, the same recommendation is Jumping in thread since first recent I came across with same brand setup. Reverse Staging. 0 and then reverse staging would be off. Air to air O/B Reversing Valve. 932. I think the outdoor min temp overrides this. 1 User Guide ecobee ©2014 ecobee 250 University Ave | Suite 400 Toronto | Ontario | M5H 3E5 Canada Toll free 1. running about 20-40 min cycles. If your old thermostat has a wire attached to the W3 or Y3 connector, it means your HVAC system has a third stage of heating (W3) or cooling (Y3). Off Auto Compressor Min On Time. com e3 -UG R001 engaging the auxiliary heat. Aux Reverse Staging ‒ Enables the second stage of the auxiliary heat to be run if the current temperature is greater than the value set for the Aux Stage 2 Temperature Delta setting. Select Aux Reverse Staging. 0 deg (the amount that triggers aux) Aux runs, along with compressor, until it goes up 1. 0 Compressor Stage 1 Max Runtime - Not Used Compressor to Aux Temperature Delta - 4. Off As noted in the ecobee 3 installation guide, the installation and set-up of this thermostat should be performed by a licensed HVAC contractor who is knowledgeable in the operations of your HVAC system. Aux Min On Time - 5 min Cool Differential - 1 F Cool Dissipation - 30 sec Compressor Min On Time - 5 min Compressor to Aux Temp Delta - Auto (unsure on this one) Compressor to Aux Run time - Auto (unsure on this one) Aux Reverse Staging - Off Temp Correction - 0 F Humidity Correction - 0 % Thermal Protect - Disabled *Compressor to Aux Runtime: Sets the time the compressor must run before switching to auxiliary heat. Here's (part of) the transcript of my conversation with Ecobee support. Aux Reverse Staging: Disengages auxiliary heat near the end of a heating cycle to rely on the heat pump. off *Manual Setting Options Heat Differential Temperature 1 User Guide ecobee3 ©2014 ecobee 250 University Ave | Suite 400 Toronto | Ontario | M5H 3E5 Canada Toll free 1. How i use it when my away Temp is 77 and home temp 73. Supplement to ecobee 3 Installation Materials Select 1 stage auxiliary heating. We gave a gas furnace for aux, so it cannot run at the same time as the HP, but with strip heaters you could have the both run at the same time. Aug 10, 2023 В· Aux Min On Time: 5min (default) Cool Diff Temp: 1. Energized on cool Aux Heat Simultaneous Operation. Aux Reverse Staging When enabled, the aux heat will be disabled when the thermostat determines that it is possible for a lower stage to finish heating to the desired setpoint. 9C. 5 degrees or 1 degree? 2- Can I use reverse staging without damaging my equipment? Reverse Staging If enabled, the thermostat will cycle down from the higher stages so that as it approaches set point it will only be running in stage 1. After doing a bit of reading on here, I have configured it to run in reverse staging with stage 2 kicking on for 2 deg delta and aux heat coming on at a 3 degree delta and aux lockout above 30 deg. Here's some more reading on those settings. Can someone advise what settings I should input for these parameters? Thanks! Aux Heat Max Outdoor Temperature? Compressor Minimum Outdoor Temperature? Aux Reverse staging on/off? Eco+ on or off? Dec 21, 2023 В· In reverse staging mode, the system starts each heating call with AUX heat, even on a 38 degree day where it could meet the setpoint with just Stage 2. " Comp to Aux temp delta: The difference between desired temperature and actual temperature at which the Aux furnace will kick in. My thinking is the more time it spends in stage one the better. ecobee. 1C This means that the temperature has to fall that far from the set point before Aux comes on. Off. 5F) Compressor to Aux Temperature Delta: 2F Sep 12, 2023 В· My Ecobee can let me set up reverse staging. 1 stage Aux Furnace. Is there a way to set up the options in the Ecobee so that it's smarter? In auto mode, it seems to just be functioning as a "dumb" timer. Context: I use reverse staging because it seems to make the best use of my heat pump and maintains an even temperature. Aux Reverse Staging: Disengages auxiliary heat near the end of a heating cycle to rely on the heat pump. Compressor Min Outdoor Temperature Step 8 Step 7 Compressor to Aux Temperature Delta Step 10 Aux Heat Maximum Step 9 Compressor to Aux Runtime I am now experimenting with Reverse Staging and Stage 2 Temperature Delta settings to try to achieve both: immediately call for stage 2 when returning from setback, and call only for stage 1 when already close to the set point, so as to run more efficiently and avoid short-cycling. The solution, for my house, seems to be to turn on "aux reverse staging. Verify the correct wiring at your furnace/air handler control board or old thermostat and ensure that the wiring at the ecobee matches. 0F Humidity Correction. com e3 -UG R003a When using Compressor Reverse Staging, the docs state "As the temperature in your home reaches the Compressor Stage 2 Temperature Delta value, the ecobee will downgrade from stage 2 back to stage 1 to finish heating/cooling your home. In other words, if the compressor to aux differential is 2 degrees, it will turn the aux on at 2 degrees below the setpoint and turn it off at 1. 5 swing for first stage then a 1 degree swing temp for stage two with reverse staging. From my understanding, regular staging will use stage 1 for a certain time and if heat is still required it will switch to stage 2 whereas reverse staging will start with stage 2 and then maintain with stage 1. +0% Thermal Protect. I use reverse staging on the AC my away temp is 79 and home temp is 72. In installation settings | Thresholds, look for Aux Max Outdoor Temperature. ecobee Smart Thermostat with voice control, ecobee4, ecobee3 Lite, ecobee3 Threshold settings allow you to configure your HVAC equipment for greater efficiency and prevent damage to your equipment by controlling how the ecobee engages it. Is this correct? Any benefit to using reverse staging for our Southern Ontario winters? Will the thermostat call for aux heat the entire time it takes to reach the desired temperature or only as long as the delta value is greater than the threshold? If you have Aux Reverse Staging enabled your ecobee should stage back down to a non-aux setting when you get closer to your setpoint. Ideally during heat I would have it go to stage 2 at a temp delta of 1. You can set a minimum that the aux runs. I have two questions: 1- Should I leave the default cool differential at . I also have "Automatic" staging and it'll only use the Aux heat to get it up past the 2. This the lockout above which Aux will never be used. The minimum number of minutes the Heatpump compressor will run for before switching to auxiliary heat. Configuring your ecobee thermostat for the first time (I’m a Pro): ecobee Smart Thermostat Enhanced provides multi-speed fan control to work with 2 /4-pipe fan coil units without On my heat pump with electric aux heat strip system, your experience seems to be correct. These adjustments can only be made on the ecobee itself, not through the Web Portal or mobile app. 0 15 seer with bosch 96% furnace. I paired it with my ecobee 4 thermostat. My settings are: Heat differential: 1F (though while checking for this message I decided to try 1. xxx, it will stage down to Stage 1 and continue at Stage 1 until room reaches 70. Aug 11, 2014 В· I have a Carrier 4-ton Performance 2-stage scroll compressor and variable speed air handler. 877. 6233 www. " as well as "If enabled, this setting will cancel out Compressor Stage 1 Max Runtime" **Aux Reverse Staging: **With this setting enabled, you will also need to enable the Aux Heat Stage 2 Temperature Delta threshold setting listed above and set a temperature value. Temperature Correction Hey everyone, we are having a cold snap in Southern Ontario which has prompted me to explore the best settings for my heat pump system’s aux heat. off *Manual Setting Options: Heat Differential Temperature Supplement to ecobee 3 Installation Materials Select Compressor Reverse Staging. If this option is enabled, the thermostat will cycle down from the higher stages so that as it approaches set point it will only be running in stage 1. If you enable Aux Reverse Staging it will then drop back to heat pump when you get back within 5 degrees. Auto Compressor to Aux Runtime The minimum number of minutes the Heatpump compressor will run for before switching to auxiliary heat. Reduce your Auxiliary Heat usage in a Heat Pump Configuration. Namely the aux heat reverse staging option. *Aux Stage 2 Temperature Delta: Sets the temperature difference before engaging the second stage of auxiliary heat. I have a ids 2. I have mine set to 2C. I have a Bosch 5ton 14SEER packaged unit with an ecobee premium installed in September this year. Auto Aux Reverse Staging When enabled, aux heat will be engaged if the current temperature is greater than the value designated in the Compressor to Aux Temperature Delta setting. 5min default Compressor to Aux Temp Delta. Switching to aux sooner will ensure your house reaches your setpoint sooner, while sacrificing some savings due to running aux instead of the heat pump. I have stage 2 to stage 1 reverse staging on, but not AUX reverse staging. It will use the aux in tandem with your heatpump to get your temp up to your auxillary setpoint differential. I bought the ecobee 3 lite specifically for the "Heat Reverse Staging" setting (or at least how I understood it) and stage 2 temp delta control, but when testing it out, it didn't work the way I thought it would. That depends on how you have your system configured. Running aux stage 2 costs more energy. 1 stage Heat Pump Type. I replaced the Edge thermostat with an Ecobee, and am working on finding the best Cooling settings. I set a longer than standard compressor off time of 600 seconds. Are we talking aux reverse staging setting? to "ON"?? Currently setting is off and thresdhold is 1. Then I set . I wasn't impressed. Read this article to see your options if you would like to install an ecobee thermostat. I opted to use the temperature settings for reverse staging as everything else is aggressively configured to not use aux. 0 Heat Differential Temp - 1. Nov 7, 2021 В· Rick007 wrote: ↑ I had a 2 stage furnace several years before purchasing the Ecobee. Not Used Aux Reverse Staging. 3F Compressor to Aux Runtime. I have Compressor Min Outdoor Temperature Disabled in the ecobee (the temp sensor outside controls the switch to gas if too cold outside) I have Compressor to Aux Temperature Delta 10*F and Compressor to Aux Runtime Disabled Aux Reverse Staging is Off Hope this helps. 9F default Aux savings differential setting, turning off Aux long before the thermostat actually reaches setpoint. 0 deg or so (this may be my "heat_diff_temp" (not sure on that). 10F Equipment Heat Pump. They werenÂ’t much help with configuring the thermostat. This will use your electric aux heat as intended for heatpumps. A second weird behavior: once the ecobee called for stage 2, either from the heat pump or aux, it would run in stage 2 until it hit the set point, then shut off the system entirely. If you have a Heat Pump installed in your home, you most likely have an auxiliary heating source, such as electric strips or gas furnace which is generally more expensive to run than your heat pump. I'm still learning about the unit and features, but this morning had an issue where the ecobee wasn't calling for heat at the set 64o threshold and apparently hadn't for hours. Heat Pump: 1 stage Type: air to air O/B Reverse Valve: energized over cool Aux Heat Simultaneous Operation: Enabled Aux Furnace: 1 stage. ) Auto Aux Reverse Staging When enabled, aux heat will be engaged if the current temperature is greater than the value designated in the Compressor to Aux Temperature Delta setting. What I found is that the time-based threshold is only available when reverse staging is turned off. Auto: Aux Reverse Staging: When enabled, aux heat will be engaged if the current temperature is greater than the value designated in the Compressor to Aux Temperature Delta setting. So leave that off if you want heat pump to be primary out the gate. Thermal Oct 30, 2022 В· The installation was professionally done. 5 degrees below the setpoint while the heat pump continues to operate. 1 User Guide ecobee3 ©2014 ecobee 250 University Ave | Suite 400 Toronto | Ontario | M5H 3E5 Canada Toll free 1. Off *Manual Setting Options The reverse staging tells it that when it's in stage 2, and the delta between desired and current temp drops below the stage 2 delta threshold, it falls back to stage 1 to prolong the compressor runtime. com e3 -UG R001 compressor reverse staging: true aux reverse staging: true (but i also had it as false previously, didn't change the behavior) Note that the ecobee help for aux reverse staging is, i think, wrong. Compressor to Aux Runtime The maximum amount of time this stage will run before engaging the next stage. Jan 22, 2023 В· Compressor to Aux Runtime: The minimum number of minutes the Heatpump compressor will run for before switching to auxiliary heat. I have been having issues with the outdoor unit running at what seems like high speed throughout the cycle. However, the graphs and reports from ecobee won't show that aux was running, since it wasn't commanding it to run. When the room temp reaches 67. Feb 28, 2024 В· If it’s any warmer than that, the system won’t use aux heat. I have mine set to 1. ecobee thermostats only support up to two stages of heating and cooling. So, ecobee support told me to enable the "aux reverse staging" and set the "compressor to AUX temperature delta" to 3. Effect is to stop using Stage 2 when Stage 1 will achieve the heat gain needed. off *Manual Setting Options Heat Differential Temperature engaging the auxiliary heat. HVAC: Heat I use reverse staging with ac. lgycch kbyyg bcxgze qmfofy swqf ulsm lmdlkq fikcaok clockx kysd